Water-Cooled Cable for Induction & Arc Furnaces

ZZLZ series flexible water-cooled cables carry the furnace current between the power supply, the short network and the furnace body while cooling water runs through the conductor. Cross sections from 50 to 9,000 mm² (1/0 AWG to 18,000 MCM), any length, any electrode design — made to your drawing or copied from the cable you are replacing.

Water-cooled cable for induction furnace

Product overview

A water-cooled cable is a flexible high-current conductor with a cooling water circuit inside it. Stranded copper carries the current, water flowing through the cable removes the heat, and a carbon-free rubber hose seals and insulates the assembly. Because the copper runs cool, a water-cooled cable carries several times the current of a dry cable of the same size and stays flexible enough to follow a tilting furnace or a swinging electrode arm.

Large cross section cables connect the short network to the electrode arms, carrying very high current while allowing the arms to lift and swing. They are used mainly on steelmaking electric arc furnaces, ladle furnaces and induction furnaces, and with a high-temperature outer sleeve they also suit submerged arc furnaces.

Every cable is built to order. Send a drawing, the specification, or simply photos and the main dimensions of your existing cable, and we manufacture an identical replacement.

At a glance

  • Conductor cross section 50–9,000 mm² (1/0 AWG–18,000 MCM)
  • Working water pressure 0.6 MPa (87 psi)
  • Dielectric strength 10,000 V
  • Tin-plated copper electrodes, machined from solid bar
  • Carbon-free rubber outer hose, crimped with dedicated clamps
  • Any length and any terminal design

Applications

Our cables are in service on melting, heating and remelting plants worldwide.

Induction melting furnaceMedium frequency furnaceHigh frequency furnace Electric arc furnace (EAF)Ladle furnace (LF)Submerged arc furnace Vacuum furnaceInduction heating equipmentElectroslag remelting Mono & poly silicon furnaceSapphire growing furnaceHF welder & spot welder

Large cross section cable for the short network

Large cross section water-cooled cables connect the short network to the electrode arms and carry very high current while the arms lift, swing and rotate. They are used mainly on steelmaking electric arc furnaces, ladle furnaces and induction furnaces, and with a high-temperature outer sleeve they also serve submerged arc furnaces. Click any photo to enlarge.

Large cross section water-cooled cable
Large cross section water-cooled cable
Short network cable with flange electrodes
Short network cable with flange electrodes
Cable set for electrode arms
Cable set for electrode arms
Copper conductor before assembly
Copper conductor before assembly
Crimped hose and electrode joint
Crimped hose and electrode joint
Finished cables ready for dispatch
Finished cables ready for dispatch

Technical specifications

ZZLZ series, metric and US units side by side. Non-standard sizes between 50 and 9,000 mm² are made to order.

ModelCross section (mm²)US equivalentRated current (A)Cable OD (mm / in)Water connection
ZZLZ1001004/0 AWG60028 / 1.10G3/8"
ZZLZ150150300 MCM90032 / 1.26G1/2"
ZZLZ200200400 MCM1,20036 / 1.42G1/2"
ZZLZ300300600 MCM1,80042 / 1.65G3/4"
ZZLZ400400800 MCM2,40048 / 1.89G3/4"
ZZLZ5005001000 MCM3,00054 / 2.13G1"
ZZLZ6306301250 MCM3,80060 / 2.36G1"
ZZLZ8008001600 MCM4,80068 / 2.68G1-1/4"
ZZLZ100010002000 MCM6,00076 / 2.99G1-1/4"
ZZLZ120012002400 MCM7,20083 / 3.27G1-1/2"
ZZLZ150015003000 MCM9,00092 / 3.62G1-1/2"
ZZLZ200020004000 MCM12,000104 / 4.09G2"
ZZLZ250025005000 MCM15,000115 / 4.53G2"
ZZLZ300030006000 MCM18,000126 / 4.96G2-1/2"

Rated current applies with cooling water flowing at an inlet temperature up to 35 °C (95 °F). Values are indicative for selection; the figures for your cable are confirmed on the quotation drawing.

Materials

Conductor: bare or tin-plated stranded T2 copper. Electrodes: copper bar, CNC machined, tin plated. Insulation between coaxial conductors: PTFE. Outer hose: carbon-free rubber.

Water circuit

Working pressure 0.6 MPa (87 psi). Inlet and outlet nozzles in vertical or 90° form; the 90° nozzle can be turned to any position through 360°. Thread sizes G3/8" to G2-1/2" or to your pattern.

Electrical

Dielectric strength of the outer hose 10,000 V. Operating frequency from mains 50/60 Hz up to high-frequency equipment. Hollow conductors reduce skin effect and voltage drop at medium and high frequency.

Cable construction

Water-cooled cable construction, sectional view
  1. Flexible copper conductorFine stranded copper drawn and stranded on our own lines, bare or tin plated.
  2. Steel reinforcement / spring layerKeeps the bore open and stops the hose collapsing under bending and water pressure.
  3. Tin-plated protective layerProtects the copper against oxidation and keeps contact resistance low.
  4. Internal cooling water channelWater flows through the cable and carries the heat away from the conductor.
  5. Carbon-free rubber hoseSeals the water circuit and insulates the assembly, 0.6 MPa (87 psi), 10,000 V.
  6. Machined copper electrodesCrimped to the hose with dedicated clamps on purpose-built equipment, no leaks at the joint.

How to select the right cable size

Cross section follows the furnace current; length follows the distance between the power supply and the furnace plus the movement of the arm or the tilting angle; the electrode follows the existing connection on your equipment. Send us the four values below and we will propose the size.

Furnace / applicationTypical currentUsual cross sectionTypical electrode
Induction melting, 0.5–3 t1,000–3,000 A150–500 mm²Integral or standard
Induction melting, 5–15 t3,000–8,000 A500–1,500 mm²Integral or flange
Induction melting, 20–60 t8,000–20,000 A1,500–3,000 mm²Flange or parallel
EAF / ladle furnace short network20,000–60,000 A2,000–9,000 mm² per phaseFlange, coaxial
Vacuum & high-frequency equipment500–5,000 A50–800 mm² hollowIntegral, hollow flexible
Your requirement———

Ranges are for orientation only. We recommend the suitable cable size based on your current, frequency, length and furnace configuration.

Terminal & electrode options

The electrodes at both ends of a medium frequency furnace cable come in several designs, so the cable matches the connection you already have.

a. Integral electrode

Machined from one solid copper bar on CNC lathes and mills — no contact joints, no welds, no weld seams. Tin-plated surface: neat, durable and low in resistance.

b. Round flange electrode

The flange mates with the flange on your heating equipment. Quick to fit and remove, with reliable contact over the full face.

c. Parallel electrode

Two water-cooled cables share one electrode. Cable and electrode meet on a precision-machined taper, giving reliable contact and easy removal. The tin-plated surface stays smooth and resists oxidation.

d. Standard electrode

Formed from bent copper bar with a welded copper tube and a passivated surface. The conductor connects on a taper, so the cable is easy to dismantle when the outer hose is replaced — commonly called the union type.

f. Water nozzles

Inlet and outlet nozzles in vertical or 90° form. Both use a screw with lock nut and sealing ring; the 90° nozzle can be turned to any direction through 360°.

Custom terminals

Coaxial heads, busbar lugs, drilled copper pads and any pattern you send. If you have no drawing, photos of the old electrode with a few dimensions are enough.

Terminal photos

Click any photo to enlarge.

Integral machined electrode
Integral machined electrode
Round flange electrode
Round flange electrode
Parallel electrode, two cables
Parallel electrode, two cables
Standard bolted electrode
Standard bolted electrode
Vertical water nozzle
Vertical water nozzle
90° adjustable water nozzle
90° adjustable water nozzle

Product types

Five families cover almost every furnace. Each is built to your length, cross section and electrode design. Click any photo to enlarge.

Hollow water-cooled cable for high frequency furnaces

Water runs inside, current flows outside. On medium and high frequency equipment this construction reduces skin effect and voltage drop, raises current capacity and lowers losses.

Hollow high frequency furnace cable
Hollow high frequency furnace cable
Hollow conductor detail
Hollow conductor detail
Cable with machined electrode
Cable with machined electrode
Set of hollow cables
Set of hollow cables
Water nozzle connection
Water nozzle connection
Hollow cable under assembly
Hollow cable under assembly

Coaxial water-cooled cable for electric arc and submerged arc furnaces

The coaxial electrodes are machined from copper and tin plated against corrosion, with the insulating component between them made of PTFE. The two cooling circuits stay separate and the two conductors run coaxially, insulated from each other: less heat generated, lower leakage inductance, lower electrical loss, higher transmission efficiency and lower energy consumption.

The outer hose is carbon-free rubber rated for 0.6 MPa (87 psi) working water pressure and 10,000 V dielectric strength. Hose and electrode are sealed with a dedicated clamp, crimped on purpose-built equipment. Coaxial cable heads are available in several designs for the customer to choose from.

Coaxial water-cooled cable
Coaxial water-cooled cable
Coaxial electrode head
Coaxial electrode head
PTFE insulating component
PTFE insulating component
Tin-plated coaxial electrode
Tin-plated coaxial electrode
Crimped clamp connection
Crimped clamp connection
Coaxial cable for submerged arc furnace
Coaxial cable for submerged arc furnace
High-current coaxial cable
High-current coaxial cable
Coaxial head, alternative design
Coaxial head, alternative design
Separate water circuits
Separate water circuits
Coaxial cable assembly
Coaxial cable assembly
Coaxial cable set
Coaxial cable set
Coaxial cable in service
Coaxial cable in service

Large hollow flexible cable for vacuum furnaces

Large hollow flexible cables for vacuum melting and heat treatment plants, built for high current in a tight bending radius inside the equipment.

Large hollow flexible vacuum furnace cable
Large hollow flexible vacuum furnace cable
Hollow flexible conductor
Hollow flexible conductor
Vacuum furnace cable with electrodes
Vacuum furnace cable with electrodes

Hollow flexible soft cable for high frequency, vacuum and medium frequency furnaces

A hollow cable carries water on the inside and current on the outside. On medium and high frequency equipment it reduces skin effect, cuts voltage drop, raises current capacity and lowers losses — the ideal replacement for traditional solid stranded cable.

Hollow flexible soft water-cooled cable
Hollow flexible soft water-cooled cable
Hollow conductor cross section
Hollow conductor cross section
Flexible hollow cable coil
Flexible hollow cable coil
Cable with integral electrode
Cable with integral electrode
Cable with flange electrode
Cable with flange electrode
Tin-plated conductor detail
Tin-plated conductor detail
Hollow cable assembly line
Hollow cable assembly line
Cable set for high frequency equipment
Cable set for high frequency equipment
Water connection detail
Water connection detail
Finished hollow flexible cables
Finished hollow flexible cables

Vacuum furnace water-cooled cable

Standard water-cooled cables for vacuum furnace power feeds, with electrodes matched to the feed-through on your equipment.

Vacuum furnace water-cooled cable
Vacuum furnace water-cooled cable
Cable with vacuum feed-through electrode
Cable with vacuum feed-through electrode
Cable pair for vacuum furnace
Cable pair for vacuum furnace
Vacuum furnace cable detail
Vacuum furnace cable detail

Medium frequency furnace cable & non-standard sizes

The standard cable for induction melting, and any single conductor cross section between 50 and 9,000 mm² made to your drawing or to your requirement when no drawing exists.

Medium frequency furnace water-cooled cable
Medium frequency furnace water-cooled cable
Cable set for induction melting furnace
Cable set for induction melting furnace
Non-standard cable to customer drawing
Non-standard cable to customer drawing
Cables packed for export
Cables packed for export

Custom water-cooled cable

Water-cooled cables are manufactured according to customer drawings, existing cable samples, furnace specifications and terminal dimensions. Most of our export orders are replacements for cables originally supplied with the furnace, and in almost every case photos plus a few measurements are enough for us to reproduce the part.

Our own drawing, tinning, stranding and assembly lines sit in one plant, so urgent replacements move quickly and your furnace goes back into production sooner.

Please send

  • Drawing, or photos of the existing cable
  • Cable length
  • Current and frequency
  • Conductor cross section
  • Terminal type and dimensions
  • Water connection size
  • Furnace brand, model and capacity
  • Quantity

Manufacturing process

01Copper material
02Wire drawing & tinning
03Copper stranding
04Conductor forming
05Electrode machining
06Cable assembly
07Hose assembly & crimping
08Pressure testing
09Electrical testing
10Final inspection
11Packing & shipment

Quality control & testing

  • Dimension inspection against the approved drawing
  • Copper conductor inspection, cross section and plating
  • Water pressure test at 0.6 MPa (87 psi)
  • Leakage test on the complete assembly
  • Electrical insulation test, 10,000 V dielectric strength
  • Terminal inspection, taper fit and contact face
  • Appearance inspection of hose, clamps and plating
  • Final assembly inspection before packing

Test records are issued with each shipment. Packing is in fumigation-free wooden cases or on pallets, marked to your instructions.

Application photos

Click any photo to enlarge.

Induction melting furnace installation
Induction melting furnace installation
Electric arc furnace short network
Electric arc furnace short network
Ladle furnace connection
Ladle furnace connection
Vacuum furnace power feed
Vacuum furnace power feed

Frequently asked questions

What is a water-cooled cable?
It is a flexible high-current cable with cooling water running through it. The stranded copper carries the current, the water removes the heat, and a rubber hose seals and insulates the assembly, so the cable carries far more current than a dry cable of the same cross section.
Where are water-cooled cables used?
Induction melting and heating furnaces, medium and high frequency equipment, electric arc furnaces, ladle furnaces, submerged arc furnaces, vacuum furnaces, electroslag remelting, silicon and sapphire growing furnaces, high-frequency welders and spot welders.
How do I select the correct cable size?
Start from the furnace current and frequency, then the length needed for the movement of the arm or tilting of the furnace, then the electrode that matches your existing connection. Send us those values and we will propose the cross section and the electrode design.
Can you manufacture according to our drawing?
Yes. Drawings are followed exactly, and we confirm any point that looks unclear before cutting material.
Can you copy an existing cable?
Yes, and this is how most replacement orders are handled. Send photos of the cable and the electrodes together with the length, the cross section and the electrode dimensions, and we prepare a manufacturing drawing for your approval.
What terminal types are available?
Integral machined electrodes, round flange electrodes, parallel electrodes for two cables, standard bolted electrodes, coaxial heads and custom patterns. Water nozzles are vertical or 90°, and the 90° nozzle turns through a full 360°.
What is the maximum working water pressure?
The outer hose is rated for 0.6 MPa (87 psi) working water pressure, and every assembly is pressure tested before shipment. The hose also withstands 10,000 V.
Can you supply cables for furnaces of other makes?
Yes. We produce replacement cables that match the original part on furnaces of any make. We are an independent manufacturer and are not affiliated with any furnace brand; cables are supplied as compatible replacements built to your dimensions.
What is the lead time?
It depends on the cross section and quantity, and is confirmed on the quotation. Because drawing, stranding, machining and assembly all run in our own plant, urgent replacements can be prioritised.

Related products

Request a quote

Tell us about the cable you need, or attach the drawing by email. We reply with price, weight, lead time and packing, normally within 24 hours.

  • Replacement cables for furnaces of any make
  • Pressure and dielectric test records with every shipment
  • Export packing in fumigation-free cases